Job Site Issues to Consider/Concerns
The following list of items should be considered prior to selecting an operator for a given job site.
1-Available power supply.
2-Type of door.
3-Potential operator mounting obstructions. Items to consider include, but are not limited to: side room, room above door shaft, room below door shaft, available mounting
surface integrity, power supply location, and convenient chain hoist and release cable positioning.
4-Size of door for appropriate operator torque and door travel speed selection.
5-Operator mounting environment. Items to consider include operator location and dampness,
6-Door activation needs/requirements. Examples include 3 button control stations, 1 button control stations, radio controls, pull cords, loop detectors, photoelectric controls,
key switches, etc. See "Entrapment Protection" section below.
7-Interlock switches are required under certain conditions for doors with pass doors and door locks. See page 5.5.
8-Accessory equipment. Examples are reversing edges and/or photocell beams (required for doors set to operate as momentary contact, ) , auxiliary control relays, warning lights, etc.
ENTRAPMENT PROTECTION
The installation of a fail safe external reversing device (such as a monitored reversing edge or photocell system, etc.) is required on all momentary contact electronically
operated commercial doors. If such a reversing device is not installed, the operator will revert to a constant contact control switch for operation (Closing only).
The Reversing Devices currently UL Approved with are:
1)
MillerEdge ME, MT and CPT series monitored edge sensors used in combination with Timer-Close Module P/N OPABTCX.S, or OPAKMEIGX.S INTERFACE MODULE.
2) Residential Safe-T-Beam® Monitored Photocells from The Genie® Company, model OSTB-BX (P/N 38176R).
3) Series II Commercial Safe-T-Beam®, Monitored Photocells P/N OPAKPE.S.
4) Series II Commercial Safe-T-Beam®, Monitored Photocells for NEMA4, P/N OPAKPEN4GX.S.
WARNING:
CAUTION:
Check working condition of door before installing the operator. Door must be free from sticking and binding. If equipped, deactivat
any door locking device(s). Door repairs and adjustments, including cables and spring assemblies MUST be made by a trained service
representative using proper tools and instructions.
New Features:
Multivolt
Multivolt
— Offers all (available) voltage combinations in both single, and 3-phase units.
E
Z Limit
— F
eatures patent pending electro-mechanical design that sets limits through the control panel that are maintainable even through a power outage.
TensiBelt
— Employs a self-adjustment feature for tensioning.
GCL-J&H
Standard Duty Operator
Section 3: Critical Installation Information
DO NOT apply line voltage until instructed to do so.
www.geniecompany.com
dustiness
and corrosiveness of the location.