Genie GCL-J&H Installation Manual page 10

Jackshaft/hoist standard duty commercial/industrial door operator
Table of Contents

Advertisement

Chain Couple (continued)
For Hollow Counterbalance Door Shaft:
1) Use non-threaded hole in door shaft sprocket as a guide and
drill a 3/8" diameter hole through one side of the door shaft.
Fig. 3A.
2) Insert clevis pin through sprocket and shaft to hold sprocket
in position.
3) Drill through opposite side of shaft to obtain proper hole
alignment. Fig. 3B.
4) Insert clevis pin through both holes and secure with cotter pin.
Fig. 3C.
For Solid Counterbalance Door Shaft:
1) Insert key into door shaft keyway.
2) Slide sprocket into place and secure with set screws.
To Complete the Installation:
If needed, realign operator sprocket with door sprocket. If you have
excessive door shaft movement, an optional chain tension plate is
available. Fig. 4
p ,
g
4
. 4 .
GCL-J&H
Standard Duty Operator
www.geniecompany.com
SPROCKET HUB
DOOR SHAFT
Figure 3A
(TUBE)
CLEVIS PIN
Figure 3B
DOOR SHAFT
(TUBE)
CLEVIS PIN
Figure 3C
DOOR SHAFT
(TUBE)
DRILL HOLE
IN THIS SIDE
OF SHAFT
DRILL HOLE IN
OPPOSITE SIDE
OF SHAFT
COTTER PIN