Genie GCL-J&H Installation Manual page 52

Jackshaft/hoist standard duty commercial/industrial door operator
Table of Contents

Advertisement

Error Code Displays
Condition
Code
DISPLAY
REV > PHOTOCELL
46
REV > N-C SAFETY
47
REV > MON. EDGE
48
REV > DOOR FORCE
49
REV > LOSS OF C/C
4A
REV > MAX RUN TMR
4B
4F
REV > EXP MOD FAIL
STOP > HOT MOTOR
50
STOP > OPEN MRT
51
STOP > CLOSE MRT
52
53
STOP > BRAKE FAULT
STOP > OPEN INTLK
57
STOP > WRONG GDO
58
STOP > DOOR FORCE
59
STOP > WRONG LIMIT
5A
5B
STOP > WRONG DIR
STALL > DOWN LIMIT
5C
STALL > UP LIMIT
5D
5E
STALL > MID-STOP
5F
STALL > NO LIMIT
60
CHECK STOP BTN
61
TCM DISABLED
NO RADIO >> C/C
62
63
CHECK AUX OPEN
64
CHECK STOP KEY
65
CHECK N-O SAFETY
66
CHECK PHOTOCELL
67
CHECK N-C SAFETY
68
CHECK MON. EDGE
69
OVERHEATED MOTOR
6A
POWER WIRING ERROR GDO WON'T RUN BECAUSE POWER SUPPLY WIRED INCORRECTLY
6B
FIRE DOOR SHTDN
6C
NO RUN > DOWN LIM
6D
NO RUN > UP LIMIT
6E
NO RUN > MID STOP
6F
EXP MODULE FAIL
GCL-J&H
Standard Duty Operator
Section 10: Appendix C
Condition Code Description
GDO REVERSED BECAUSE THE PHOTOCELL WAS BLOCKED
GDO REVERSED BECAUSE THE N-C REVERSING INPUT WAS ACTIVATED
GDO REVERSED BECAUSE THE MONITORED EDGE SENSOR WAS ACTIVATED
GDO REVERSED BECAUSE THE FORCE REQUIRED TO CLOSE THE DOOR WAS TOO HIGH
GDO REVERSED BECAUSE CONSTANT CONTACT ON THE CONTROL WAS REMOVED BEFORE REACHING THE DOWN LIMIT
GDO REVERSED BECAUSE THE CLUTCH SLIPPED OR SOME OTHER FAULT OCCURRED THAT ALLOWED THE GDO TO RUN TOO LONG
GDO REVERSED BECAUSE AN EXPANSION MODULE WAS NOT WORKING PROPERLY
GDO STOPPED BECAUSE THE MOTOR WAS OVERHEATED
GDO STOPPED BECAUSE THE CLUTCH SLIPPED OR SOME OTHER FAULT OCCURRED THAT ALLOWED THE GDO TO RUN OPEN TOO LONG
GDO STOPPED BECAUSE THE CLUTCH SLIPPED OR SOME OTHER FAULT OCCURRED THAT ALLOWED THE GDO TO RUN DOWN TOO LONG
GDO STOPPED BECAUSE OF BRAKE ERRONEOUSLY ENGAGED
GDO STOPPED BECAUSE THE HOIST INTERLOCK OR EXTERNAL INTERLOCK IS OPEN
GDO STOPPED BECAUSE THE BOARD IS SET FOR JACKSHAFT MODE, BUT INSTALLED IN A TROLLEY OPERATOR
GDO STOPPED BECAUSE THE FORCE REQUIRED TO OPEN THE DOOR WAS TOO HIGH
GDO STOPPED BECAUSE THE UP LIMIT ACTIVATED WHEN CLOSING OR THE DOWN LIMIT ACTIVATED WHEN OPENING
GDO STOPPED BECAUSE THE DOOR MOVED IN THE WRONG DIRECTION
GDO STOPPED BECAUSE IT COULDN'T LEAVE THE DOWN LIMIT DUE TO A SLIPPING CLUTCH OR OTHER PROBLEM
GDO STOPPED BECAUSE IT COULDN'T LEAVE THE UP LIMIT DUE TO A SLIPPING CLUTCH OR OTHER PROBLEM
GDO STOPPED BECAUSE IT COULDN'T LEAVE THE MID-STOP LIMIT DUE TO A SLIPPING CLUTCH OR OTHER PROBLEM
GDO STOPPED BECAUSE TRAVEL LIMITS HAVE NOT BEEN SET
GDO WON'T RUN BECAUSE THE STOP BUTTON IS ACTIVE
TIMER CLOSE WON'T WORK BECAUSE NO SAFETIES ARE ENABLED
RADIO INPUT WON'T WORK WITH OPEN OR CLOSE FUNCTION IN CONSTANT CONTACT MODE
GDO WON'T CLOSE BECAUSE AUXILIARY OPEN INPUT IS ACTIVE
GDO WON'T RUN BECAUSE THE KEYPAD STOP KEY IS ACTIVE
GDO WON'T CLOSE BECAUSE THE N-O REVERSING IS ACTIVE
GDO WON'T CLOSE BECAUSE THE PHOTOCELL IS BLOCKED
GDO WON'T CLOSE BECAUSE THE N-C REVERSING INPUT IS ACTIVE
GDO WON'T CLOSE BECAUSE THE MONITORED EDGE SENSOR IS ACTIVE
GDO WON'T RUN BECAUSE THE MOTOR IS OVERHEATED
GDO WON'T RUN BECAUSE OF LOSS OF POWER
GDO WON'T CLOSE BECAUSE ITS ALREADY AT THE DOWN LIMIT
GDO WON'T OPEN BECAUSE ITS ALREADY AT THE UP LIMIT
GDO WON'T RUN BECAUSE ITS AT OR ABOVE THE MID-STOP LIMIT & CAN'T RUN UP & A REVERSING INPUT IS PREVENTING IT FROM CLOSING
GDO WON'T RUN BECAUSE AN EXPANSION MODULE FAILURE IS PREVENTING IT