Sectional Door Chart - Genie GCL-J&H Installation Manual

Jackshaft/hoist standard duty commercial/industrial door operator
Table of Contents

Advertisement

Model
HP
UL L is ted
GCL-J&H
1/2
Y es
GCL-J&H
3/4
Y es
GCL-J&H
1
Y es
T=Trolley
S=Jackshaft,SideMount C=Jackshaft,CenterMount
Note: Total door weight, and not the square footage, is the critical factor in selecting the proper operator.
Square footage measurements are based on "square doors." (Example=16' x 16')
NOTE: Doors that require special windloading and wide doors, normally require increased strutting (reinforcement). Strutting doors can significantly increase door
weight beyond weight shown. Consult Customer Service for the impact of wind load andstrutting on square foot limits.
NOTE: "PU-FIP" stands for "polyurethane, foamed-in-place." If no notation is present, insulation is "polystyrene, layed-iin-place."
1) READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2) Install only on a properly operating and balanced door. A door that is operating
improperly could cause severe injury. Have qualified service personnel make
repairs to cables, spring assemblies and other hardware before installing the operator.
3) Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically
and/or electronically interlocked to the power unit) that are connected to the door
before installing the operator.
GCL-J&H
Standard Duty Operator
Section 3: Critical Installation Information
Sectional Door Chart (sq. ft.)
CommercialSteelInsulated&Non-Insulated
Door S eries ->
216
216 ins.
220
Max.
16GA.
16GA.
20GA.
Door
Flush
Mounting
Flush
Ribbed
Type
Weight
Steel
Steel
Steel
(Lbs)
Insulated
TSC
1120
256
220
370
TSC
1370
330
256
440
TSC
1620
380
280
500
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING -To reduce the risk of severe injury or death:
www.geniecompany.com
220 ins.
2415
2415 ins.
2411
2411 ins.
20GA.
24GA.
Nominal
Nominal
24GA.
Ribbed
Ribbed
24GA.
24GA.
Ribbed
Steel
Steel
Ribbed
Ribbed Steel
Steel
Insulated
Insulated
Steel
Insulated
256
440
340
320
320
310
530
400
320
320
370
570
410
320
320
4) Install door operator at least 8 feet above floor if operator has exposed moving parts.
5) Do not connect the door operator to the power source until instructed to do so.
6) Locate the control station: (a) within sight of door, (b) a minimum of 5 feet above
floor so that small children cannot reach it, and (c) away from all moving parts of door .
7) Install the Entrapment Warning Placard next to the control station and in a
prominent location.
8) For products having a manual release, instruct the end user on the operation of the
manual release.
Thermospan
Thermomark
125
150
200
200-20
5150
5200
PU/FIP
PU/FIP
PU/FIP
Insulated
Insulated
Insulated
PU/FIP
PU/FIP
PU/FIP
2"
Raised
Raised
Insulated
Insulated
Insulated
20GA.
Panel
Panel
1.38"
2"
Exterior
1.38"
256
360
400
300
400
256
450
450
370
460
256
480
480
420
500
0 -12
Aluminum
451
452
1/4" or 1/2"
1/8" Glass
Glass
1.38"
1.38"
2"
380
360
240
440
400
330
480
400
400
3.3