Interlock Switches
(Rolling Steel)
1) Optional external interlock switches
are required with some Sectional or
Rolling Steel Doors to prevent the
door from operating under certain
conditions including the following:
If the door is equipped with a
functioning door lock, an
interlock switch (A) must be
installed to prevent electric
operation when the lock
is engaged.
If the door is equipped with a
pedestrian pass-through door,
an interlock switch (B) must be
installed at the pass-through
door in order to prevent
electrical operation when the
pass-through door is open.
The Switches must be set in
the field.
Figure 6
GCL-J&H
Standard Duty Operator
NOTE: If External Interlock is used, THE JUMPER WIRE BETWEEN THE EXT INTLK TERMINALS MUST BE REMOVED.
Pass door interlock:
Should be open when
door is open.
Closed when door is
closed.
B
A
Side lock interlock:
Should be open when door is locked.
Closed when door is unlocked.
www.geniecompany.com
OPEN
CLOSE
SWITCH
075412-0000
(N.O.)
ANGLE
405964-0000
Switches must
be set in
the field.
SWITCH
075396-0000
(N.C.)
CONTROL SIGNAL TERMINAL STRIP
ODC
ODC
NO
NO
EXT
STOP
GND
1BTN
STB
STB
REVERSE REVERSE
INTLK
STANDARD
SLIDELOCK
TRACK
0 -12
EXT
INTLK
5.5