Setting Limit Overrun - Genie GCL-J&H Installation Manual

Jackshaft/hoist standard duty commercial/industrial door operator
Table of Contents

Advertisement

Setting Limit Overrun

AL
U
This Setting is a matter of trial and Error
1) If operator is in RUN mode, press CAL/RUN
calibration mode.
2) Press SCROLL
key until display reads "LIMIT OVERRUN>#" where # is
SCROLL
the increment of travel beyond the CLOSE Limit ranging from 0 to 9. Zero
turns off the Overrun function and the door stops at the DOWN Limit.
CLEAR
Nine is the maximum distance the door will travel past the limit. This
function is used to insure a good seal at the bottom of the door.
Figure 9.
SET
3) Press SET/CLEAR
key to toggle between 0 and 9—one digit at a time.
CLEAR
4) Pick a value and operate the door. Adjust as necessary.
5) Press a SCROLL
SCROLL
key to shift to a new function and lock in the setting.
CAL
6) Press CAL/RUN
key to return to run mode.
RUN
GCL-J&H
Standard Duty Operator
key to enter
CAL
RUN
CL E
NOTE: The actual distance that the Overrun function covers is variable depending
on model of operator and size of the door (nominally about 2 inches of travel).
WARNING:
reversing devices, including photocells and sensing or reversing edges.
Therefore, any externally connected devices will be disabled during that
portion of door travel which is controlled by the Limit Overrun function.
Figure 9
www.geniecompany.com
The Limit Overrun function will override external
LIMIT OVERRUN #
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
0 -12
OPEN
CLOSE
STOP