Setting Mid-Stop Limit - Genie GCL-GCX Manual

Commercial line counter door operator
Hide thumbs Also See for GCL-GCX:
Table of Contents

Advertisement

Setting Mid-Stop Limit

The operator includes a programmable Mid-Stop. This feature allows
the operator to stop at a user selectable point when opening. It is used
when operating very tall doors that only open to their full height
occasionally. The Mid-Stop does not effect the operator when closing. To
operate door to full open position from mid-stop, press open button again.
NOTE: Setting of the MID-STOP should only be performed AFTER Travel
Limit and Max Run Timer settings have been made.
1) Press CAL/RUN
CAL
to enter calibration mode.
RUN
2) Press the CLOSE
to close the door to the down limit.
CLOSE
until display reads "MID-STOP > CLR" Figure 14
3) Press SCROLL
SCROL
NOTE: If the display reads MID-STOP > SET at this point, first clear
MID-STOP as described below then repeat steps 1-3 and continue.
4) Press the OPEN
to open the door to desired mid-stop height.
OPEN
SET
until the display reads "MID-STOP > SET"
5) Press SET/CLEAR
CLEAR
AL
6) Press CAL/RUN
to return to run mode.
CAL
RUN
To CLEAR the Limit
CAL
1) Press CAL/RUN
to enter calibration mode.
RUN
until display reads "MID-STOP > SET"
3) Press SCROLL
SCROLL
SET
until the display reads "MID-STOP > CLR"
5) Press SET/CLEAR
CLEAR
8) Press CAL/RUN
to return to run mode.
RUN
GCL-GCX
Counter Door Operator
www.geniecompany.com
OPEN
MID-STOP SET
CLOSE
STOP
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 14
08-12