Error Codes - Genie GCL-J&H Installation Manual

Jackshaft/hoist standard duty commercial/industrial door operator
Table of Contents

Advertisement

Error Codes Displays (continued)
Condition
DISPLAY
Code
70
BOARD FAILURE 70
71
BOARD FAILURE 71
74
BOARD FAILURE 74
75
BOARD FAILURE 75
76
BOARD FAILURE 76
77
BOARD FAILURE 77
80
BOARD FAILURE 80
81
BOARD FAILURE 81
82
BOARD FAILURE 82
83
BOARD FAILURE 83
84
BOARD FAILURE 84
85
EXP PORT PROBLEM
86
BOARD FAILURE 86
87
IEM FAILURE
88
TCM FAILURE
89
FDM FAILURE
8A
AOM FAILURE
8B
SPARE MOD FAILURE
8C
LOW SYSTEM VOLTS
8D
HI SYSTEM VOLTS
8E
REV INTERRUPTED
8F
LIMIT MOD. FAIL
90
DIAGNOSTIC MODE
OPEN BTN BAD > PU
A0
A1
CLOSE BTN BAD > PU
A2
ONE BTN BAD > PU
A3
RADIO BAD > PWR UP
AUX OPEN BAD > PU
A4
A5
OPEN KEY BAD > PU
A6
CLOSE KEY BAD > PU
MULT KEYS BAD > PU
A7
AA
TCM BAD > POWER UP
AB
FDM BAD > POWER UP
B0
OPENING > XMTR #
B1
CLOSING > XMTR #
B2
HALT > XMTR #
B3
NO XMTR > CC
GCL-J&H
Standard Duty Operator
Section 10: Appendix C
Condition Code Description
CONTROL BOARD FAILURE 70, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 71, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 74, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 75, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 76, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 77, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 80, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 81, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 82, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 83, CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 84, CONTACT FACTORY TECHNICAL SERVICE DEPT.
EXPANSION PORT IS SHORT CIRCUITED, TRY DISCONNECTING EXPANSION MODULES OR CONTACT FACTORY TECHNICAL SERVICE DEPT.
CONTROL BOARD FAILURE 86, DISCONNECT EXPANSION MODULES. IF NO CHANGE, CONTACT FACTORY TECHNICAL SERVICE DEPT.
RESERVED--NOT CURRENTLY USED
TIMER CLOSE MODULE (TCM) HAS FAILED
FIRE DOOR MODULE (FDM) HAS FAILED
AUXILIARY OUTPUT MODULE (AOM) HAS FAILED
RESERVED--NOT CURRENTLY USED
POWER SUPPLY LINE VOLTAGE LOW
POWER SUPPLY LINE VOLTAGE HIGH
GDO LOST POWER OR ENCOUNTERED ANOTHER PROBLEM DURING THE REVERSAL PROCESS, REVERSAL IS COMPLETING NOW
GDO WON'T RUN, LIMIT MODULE HAS FAILED
GDO IS IN DIAGNOSTIC MODE, NORMAL FUNCTIONS ARE NOT ALLOWED
OPEN & CLOSE BUTTONS WON'T WORK, THE OPEN BUTTON WAS ACTIVE WHEN THE GDO WAS POWERED-UP
OPEN & CLOSE BUTTONS WON'T WORK, THE CLOSE BUTTON WAS ACTIVE WHEN THE GDO WAS POWERED-UP
1 BUTTON WON'T WORK, THE 1 BUTTON WAS ACTIVE WHEN THE GDO WAS POWERED-UP
RADIO INPUT WON'T WORK, THE RADIO INPUT WAS ACTIVE WHEN THE GDO WAS POWERED-UP
AUXILIARY OPEN INPUT WON'T WORK, THE AUXILIARY OPEN INPUT WAS ACTIVE WHEN THE GDO WAS POWERED-UP
KEYPAD OPEN & CLOSE KEYS WON'T WORK, THE OPEN KEY WAS ACTIVE WHEN THE GDO WAS POWERED-UP
KEYPAD OPEN & CLOSE KEYS WON'T WORK, THE CLOSE KEY WAS ACTIVE WHEN THE GDO WAS POWERED-UP
1 OR MORE KEYPAD CALIBRATION KEYS WON'T WORK, 1 OR MORE WERE ACTIVE WHEN THE GDO WAS POWERED-UP
RESERVED--NOT CURRENTLY USED
RESERVED--NOT CURRENTLY USED
OPENING FROM TRANSMITTER # __
CLOSING FROM TRANSMITTER # __
HALT FROM TRANSMITTER # __
NO CONTROL FROM TRANSMITTER, CONSTANT CONTACT EMPLOYED AT LOCAL CONTROL
www.geniecompany.com
10.12
0 -12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents