2-54
(1) T1IB and (1) BRIB
If both cards in a phone switch are connected to a telephone company
clock (not point-to-point T1), put the T1 clock switch in the enable
position (ON) to allow it to receive clocking from the telephone company
directly. Do not install the clock cable. Set the BRIB clock switch in the
disable position (OFF), which allows the BRIB to synchronize its timing off
of the backplane (from the T1 clocking). If the T1 is a point-to-point T1,
set the BRIB to the enable position (ON), the T1 in the disable position
(OFF), and do not install the clock table.
(2) PRIBs and (3) T1IBs
PRIB1
SW2 On
The clock cable should be connected to the OUT position on the
connector on the PRIB1. The clock cable should be connected to the IN
position on PRIB2. SW2 of the PRIB1 and PRIB2 should be placed in the
T1IB
SW3 On
PRIB2
T1IB1
SW2 On
SW3 Off
BRIB
Switch 4, SW2 Off
T1IB2
SW3 Off
CO/PBX Connections
T1IB3
SW3 Off

Advertisement