To connect the power cord from the server to an uninterruptive power supply (UPS), use service
outlets on the rear of the UPS.
The UPS service outlets are categorized into two groups: SWITCH OUT and UN-SWITCH OUT.
(They may be called "OUTPUT1" and "OUTPUT2".)
To control power supply with an application (NEC ESMPRO/UPSController) that controls the UPS,
connect the power cord to an SWITCH OUT outlet.
For constant power supply, connect the power cord to a UN-SWITCH OUT outlet. (Connect the
modem that is in service for 24 hours to this outlet.)
<Example>
When the power cord from the server to a UPS, change the BIOS setup of the server to link with
power supply from the UPS.
To power on the server from the UPS (Uninterruptible Power Supply), select [Server] - [AC-LINK]
- [Power On].
Change a parameter for "AC-LINK" under the Server menu of the BIOS SETUP utility. See
Chapter 4 for details.
2
O U TP U T
(U N S W ITC H O U T)
AC 100V 50/50H Z
UN-SWITCH OUT
(OUTPUT 2)
Setting Up Your Server 3-19
O U TP U T(S W ITC H O U T)
SWITCH OUT
(OUTPUT 1)