The following describe the clearing procedure.
Observe the following instructions to use the server safely. Failure to follow
these instructions may result in death or serious personal injury. See pages
1-3 to 1-8 for details.
Observe the following instructions to use the server safely. Failure to follow
these instructions may result in death or serious personal injury. See pages 1-
3 to 1-8 for details.
1.
See the section "Preparing for Installation and Removal" as described in Chapter 9 of this
guide to prepare.
2.
Remove the logic cover.
3.
Locate the position of the jumpers on the mother board you are changing.
4.
For clearing the BIOS password, remove the jumper strap on the BIOS password clear
jumper. For Clearing the CMOS, move the jumper strap to the CMOS clear position.
Refer to the previous illustration to find the location of the jumper.
5.
Wait for a while (about 5 seconds), and then reinstall the jumper block to the default
position.
6.
Reinstall the server removed in Step 2.
7.
Plug the power cord to your server and turn on the server.
8.
Press F2 at the prompt to run the BIOS SETUP utility, and select "Load Setup Defaults"
at the Exit menu.
Do not disassemble, repair, or alter the server.
Do not remove the lithium battery.
Do not connect the ground line to a gas pipe.
Never attempt to lift the server only by yourself.
Make sure to complete board installation.
Do not install the server on a rack with leaving covers removed.
Do not pinch your finger with mechanical components.
Note high temperature.
Do not pull out a device from the rack if the rack is unstable.
Do not leave more than one device being pulled out from the rack.
Configuring Your Server 4-45