To implement some board configuration changes, you must shut down and
Important:
restart by choosing Services > Shut Down All Services (which also closes
MAXCS) and then restarting MAXCS. If this is necessary, a message will pop
up telling you so.
Using the Triton Resource Board
The Triton resource board requires no configuration. Board resources are available when
the board is installed.
The resource board has a maximum of 12 bridges for:
6-party conferencing. When an extension is trying to make a conference call, the
•
system will try to use the conference bridge on the resource board first. If conference
bridges on the resource board are all busy, the system will use the conference
bridges on the extension board, analog or VoIP board.
Workgroup supervisor silent monitoring, barge-in, and coaching.
•
For example, if two supervisors are coaching agents, only 10 bridges are left for 6-party
conferencing.
Notes:
If a supervisor tries to perform silent monitoring, barge-in, or coaching and there is no
resource board in the system, the supervisor will hear an error tone.
If the supervisor is using an IP phone, then Connect Voice Stream to Server should
be checked in the Extension Configuration window so that the system can pull the caller
and agent's voice stream to the resource board to allow the supervisor to tap into the
conversation.
Using the Triton MeetMe Conference Board
The Triton MeetMe conference board requires no configuration. Board resources are
available when it is installed. You do have to assign a MeetMe Conference extension
(select PBX > MeetMe Conference Configuration).
One MeetMe conference board is supported in a system.
In a multiple gateways installation, the MeetMe conference board can be in any
Note:
gateway server.
Configuring the Triton Analog Station Board
Double-click the Triton Analog Station board in the Boards window to open the Board
Configuration window, similar to Figure 2 on page 116. See attribute descriptions
below Figure 2. Note the following additional information:
Double-clicking a channel in the Channel Mapping List opens a Triton Analog Line
•
configuration dialog box. See "Triton Analog Station Line Properties" on page 191.
Chapter 11: Board Configuration
This option is in the
Extension Configuration window
MAXCS ACC 6.0 Administration Manual 117