1-9. Draining waste oil

1-10. Amount of oil supplied to the hook

4
3
2
1
1 -11. Replacing the fuse
WARNING :
1. To avoid electrical shock hazards, turn OFF the power and open the control box cover after about
five minutes have passed.
2. Open the control box cover after turning OFF the power without fail. Then, replace with a new fuse
with the specified capacity.
When polyethylene oiler 1 becomes filled with oil,
remove polyethylene oiler 1 and drain the oil.
1
1)
Loosen setscrew 1 and remove setscrew 1 .
2)
When screwing in adjustment screw 2 , the
amount of oil of oil pipe, left 4 can be reduced.
3)
After the adjustment, screw in setscrew 1
and fix it.
The machine uses the following three fuses :
1 For pulse motor power supply protection
1
2 For solenoid and pulse motor power supply
2
3
3 For control power supply protection
– 99 –
1. The state of standard delivery is the
position where 3 is lightly screwed
in and returned by 1.5 turns.
2. When reducing the oil amount, do
not screw in the screw once. Ob-
serve the state for approximately
half a day and screw
ing is excessive, worn-out of the
hook will result.
15A (time-lag fuse)
protection
3.15A (time-lag fuse)
2A (fast-blow type fuse)