ZEMS-VAL-NULL
indicates the type of subsystem defined event. Because the TCP/IP Subagent
process has not defined this as a private event, the DDL AS clause "undefined"
always appears in the message text following "user content."
Cause. The TCP/IP Subagent process completed process initialization after initial
startup or after a takeover by the backup process.
Effect. The startup configuration (or last saved configuration in the case of a takeover
by the backup) is used to establish connections with SNMP agent specified for the
subagent's private ztsaAgentName object and to build MIB-II values derived from the
TCP/IP process specified for the subagent's private ztsaTcpIpProcess object.
Recovery. Informational message only; no corrective action is needed.
Sample Message
96-02-08 12:21:51 \NOVA.$ZTSA

1002: ZTSA-EVT-SUBAGENT-UNAVAIL

The TCP/IP Subagent process is terminating for reasons other than an internal fault or
invalid startup configuration.
Unconditional Tokens
ZEMS-TKN-SUBJECT-MARK
ZTSA-TKN-SUBAGENT
ZEMS-TKN-EVENTNUMBER
ZEMS-TKN-CHANGE-REASON
ZEMS-TKN-STATE-PREVIOUS
ZEMS-TKN-STATE-CURRENT
ZEMS-TKN-SYMPTOM-STRING
ZEMS-TKN-USER-CONTENT
Conditional Tokens
ZEMS-TKN-UNDERLYING-OBJ-
NAME
SNMP Configuration and Management Manual—424777-006
1002: ZTSA-EVT-SUBAGENT-UNAVAIL
TANDEM.TCPIPSA.D20
Object available
\NOVA.$ZTSA:384314581,
event number: subagent-process-available,
reason: underlying-serv-up,
previous state: disconnected,
current state: connected,
user content: undefined
Value
<1> ZTSA-TKN-SUBAGENT
<2> ztsaProcessName
<3> ZTSA-EVT-SUBAGENT-OBJ-
UNAVAIL
<4> ZEMS-VAL-reason
<5> ZTSA-VAL-STATE-state
<6> ZTSA-VAL-STATE-DISCONNECTED
<7> code-location/
internal-context-text
<8> ZEMS-VAL-NULL
<9> ztsaProcessName