Dell Brocade Adapters Troubleshooting Manual page 96

Brocade adapters troubleshooting guide
Hide thumbs Also See for Brocade Adapters:
Table of Contents

Advertisement

3
Logs
4. Click OK to save the changes and close the window.
Use the following steps to adjust port logging level for Fabric Adapter ports configured in NIC mode.
1. Select an Ethernet port from the device tree.
2. Select Configure > Eth Configuration.
3. Select a value from the Port Logging Level list.
4. Click OK to save the changes and close the window.
Adjusting the port logging level through BCU
bcu log –-level <port_id> [<level>]
where:
port_id
level
Configure logging levels for HCM logs
Adjust the number of messages logged to the following HCM logs:
To adjust the logging level, use the following steps.
1. Select Configure > HCM Logging Levels to display the HCM Logging Levels dialog box.
2. Select a level on the Agent Communication Log and HCM Debug Log lists.
72
Click Apply to apply the changes.
The Eth Configuration dialog box displays.
Supported values are Log Critical, Log Error, Log Warning, and Log Info.
The ID of the port for which you want to set the log level. This could be the
PWWN, port hardware path, or user-specified port name. This could also be
the adapter-index/port-index. For example, to specify adapter 1, port 1 you
would use 1/1 as the port identification.
Critical | Error | Warning | Info
Specifies the severity level. Error is the default setting. If no level is specified,
the current log level displays.
Agent Communication Log, where all messages are exchanged between the HCM application
and the HCM Agent.
HCM Debug Log, where messages are logged locally.
Values are Trace, Debug, Info, Warning, Error, and Fatal.
Brocade Adapters Troubleshooting Guide
53-1002145-01