FCoE and Fibre Channel problems

Virtual devices not listed in name server

If virtual devices are not listed in the fabric's name server, refer to the following descriptions of
possible causes and recommended actions to help resolve the problem.
Possible Causes:
Action: Check virtual port statistics, such as FDISC sent, FDISC accept, and No NPIV support
statistics. Refer to

Adapter not registering with the name server or cannot access storage

If the adapter is not registering with the name server or cannot access storage, refer to the
following descriptions of possible causes and recommended actions to help solve the problem.
1. Possible Cause: Adapter cannot log in to the name server.
2. Possible Cause: Adapter has a problem registering with the name server.
3. Possible Cause: Adapter has a problem querying the name server for available storage.
42
If counts for FLOGI sent and FLOGI accept fabric statistics do not match, suspect fabric
problem or protocol issue between adapter and fabric.
If fabric offline counts increase and fabric maintenance is not occurring, this may indicate a
serious fabric problem. Refer to your switch troubleshooting guide to isolate and resolve the
problem.
Problem in the fabric or a protocol issue between the adapter and fabric.
NPIV is not supported or is disabled on the switch.
"Virtual port statistics"
Action: Display logical port statistics (refer to
displaying these statistics). Check for increasing name server port login (NS PLOGI) error
rejects and unknown name server port login response (NS login unknown rsp). These errors
mean that the adapter most likely cannot log in to the name server.
Action: Display logical port statistics (refer to
displaying these statistics). Check for increasing errors of the following types. These indicate
that the adapter has a problem registering with the name server:
Name server register symbolic port name identifier (NS RSPN_ID) errors.
Name server register symbolic port name identifier response (NS RFT_ID rsp) errors.
Name server register symbolic port name identifier response rejects (NS RFT_ID rejects).
Action: Display logical port statistics (refer to
displaying these statistics). Check for increasing name server "get all port ID response" (NS
GID_FT rsp), rejects (NS_GID FT rejects), or unknown responses (NS_GID FT unknown rsp).
This indicates that the adapter has a problem querying the name server for available storage.
on page 87 for methods to display virtual port statistics.
"Logical port statistics"
"Logical port statistics"
"Logical port statistics"
Brocade Adapters Troubleshooting Guide
on page 80 for details on
on page 80 for details on
on page 80 for details on
53-1002145-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 815

Table of Contents