HP XP20000/XP24000 Manual page 295

Hp storageworks xp24000/xp20000 remote web console error codes (ae131-96086, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 54 Error Codes — Part Code 6505 (continued)
Part
Error
Error Message
Code
Number
6505
58564
The Add Pair (Paircreate)
operation failed because the
specified primary data
volume is being shredded by
Data Retention Utility.
Retry the operation after the
shredding is completed.
6505
58565
The Add Pair (Paircreate)
operation failed because the
specified secondary data
volume is being shredded by
Data Retention Utility. Retry
the operation after the
shredding is completed.
6505
58566
The specified volume cannot
be registered as a journal
volume because the volume
is being shredded by Data
Retention Utility.
Retry the operation after the
shredding is completed.
6505
58590
The Add Pair (Paircreate)
operation or the Resume Pair
(Pairresync) operation failed
because the journal volumes
of the specified master
journal group were blocked.
6505
58591
The Add Pair (Paircreate)
operation or the Resume Pair
(Pairresync) operation failed
because the journal volumes
of the specified restore
journal group were blocked.
6505
58592
The specified operation failed
because the subsystem was
being powered on or
powered off.
6505
58593
The storage system accepted
the request normally,
however the processing
requires some time. If this
message is displayed after a
setting operation, refresh the
window and check the setting
to see if it is reflected. If the
setting is not reflected despite
refreshing the window, retry
the operation.
6505
58594
The Paircreate operation
failed because the
configuration of the LUSE
volume was different between
the primary data volume and
the secondary data volume.
Recommended Action
Confirm that the shredding
has completed in the Data
Retention Utility window, and
then retry the operation.
Confirm that the shredding
has completed in the Data
Retention Utility window, and
then retry the operation.
Confirm that the shredding
has completed in the Data
Retention Utility window, and
then retry the operation.
Check the status of the
journal volumes of the
specified master journal
group.
Check the status of the
journal volumes of the
specified restore journal
group.
Check the status of the
storage system. Retry the
operation after the storage
system has started.
Wait for a while, and refresh
the window. If this message
is displayed after a setting
operation, check whether the
setting is reflected. When the
setting is not reflected, retry
the operation.
Check the LUSE volume
configuration of the primary
data volume and the
secondary data volume.
Remote Web Console Error Codes 295
Severity
Failure
Level
Level
W
0
W
0
W
0
W
0
W
0
W
0
W
0
W
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents