Table 52 Error Codes — Part Code 6010 (continued)
Part
Error
Error Message
Code
Number
6010
9360
The specified value exceeds
the range. Alternatively, the
relationship between the
specified values is not
appropriate.
6010
55035
If you plan to create a pair
with the specified LUSE
volumes, a DKC path is
required.
6010
55202
The subsystem specified by
Controller ID is not available
for the particular CU selected
from the tree.
6010
55203
There are no initiator ports
that can be used by the
subsystem specified by
Controller ID.
6010
55204
The M-VOL or R-VOL is not
supported by the specified
RCU.
6010
56537
There are no consistency
groups available for the CLPR
of the specified volumes.
Register the consistency
groups and then retry the
operation.
6010
56540
The size of the specified file
exceeds 8 megabytes, so the
file cannot be uploaded.
6010
59001
Are you sure you want to
cancel the change operation
of the option parameter that
you specified?
6010
5901 1
Are you sure you want to
output the %s file?
6010
59012
The %s file does not exist.
6010
59013
The specified file already
exists. Do you want to
overwrite this file?
6010
59025
You cannot specify two or
more pairs in the same CT
group, if Group is selected
as the Range of these pairs.
Only one pair is displayed in
the Preview list.
6010
59026
The specified RCU has been
already set. Check the RCU
parameter settings.
Recommended Action
Check the specified values
and retry the operation.
Select Add RCU command,
and then register a DKC
path.
Find the CUs that can be
used by the storage system
specified by the Controller ID.
Find the ports that can be
used by the storage system
specified by the Controller ID,
and set them as initiator
ports.
Check the settings of the
specified RCU, M-VOL and
R-VOL.
Register the consistency
groups, and then retry the
operation.
Check the size of the file,
decrease the size and retry
the operation.
To cancel the change
operation of the option
parameter, click [OK].
Otherwise, click [Cancel].
To output the file, click [Yes].
Otherwise, click [No].
Click [OK].
To overwrite the file, click
[Yes]. Otherwise, click [No].
Check the CT group or the
range of the specified pairs.
If necessary, select the pairs
again.
Check the RCU parameter
settings.
Remote Web Console Error Codes 261
Severity
Failure
Level
Level
W
0
W
5
W
0
W
0
W
0
W
0
W
0
W
0
i
0
i
0
W
0
W
0
W
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents