6.
Dispose of the old BBU.
Dispose of the used BBU according to local and federal regulations, which may
Note
include hazardous material handling procedures.
Power Supply Fan Module Removal/Replacement
!
Hot Swappable Component!
Do not operate the enclosure without adequate ventilation and cooling to the
C
AUTION
power supplies. Operating the power supplies without proper cooling may
damage their circuitry. You must shut down the controller enclosure to avoid
overheating if you take more than 15 minutes to remove the Controller Fan
Module and insert the new one.
Removing the Power Supply Fan Module
1.
Gain access to the rear of the disk array controller enclosure.
2.
Lift up on the ring/latch on the module to release the catch. See
3.
Slide the power supply fan module from the enclosure.
Figure
103.
Controller Enclosure Modules
403