Table 44
SCSI Sense Codes (cont'd)
Additional
Additional
Sense
Sense Code
Code
Qualifier
11
00
11
8A
18
02
1A
00
20
00
Interpretation
Unrecovered Read Error
An unrecovered read operation to a drive occurred and the con-
troller has no redundancy to recover the error (RAID 0,
degraded RAID 1, degraded mode RAID 3, or degraded RAID
5).
Miscorrected Data Error - Due to Failed Drive Read
A media error has occurred on a read operation during a recon-
figuration operation,
User data for the LBA indicated has been lost.
Recovered Data - Data Auto Reallocated
The controller recovered a read operation to a drive and no fur-
ther action is required by the host. Auto reallocation may not
have been used, but this is the only standard ASC/ ASCQ that
tells the initiator that no further actions are required by the
driver.
Parameter List Length Error
A command was received by the controller that contained a
parameter list and the list length in the CDB was less than the
length necessary to transfer the data for the command.
Invalid Command Operation Code
The controller received a command from the initiator that it
does not support.