actual ArrayID must be used here. An alias cannot be used because alias names are not
recorded in the log file.
Command Example
The following example displays the major event log entries for disk array rack_1. The log
entries displayed are limited to only critical entries, and entries made after 0900 on 15 May
2000.
amlog -s 05150000 -t mel -c rack_1
Sample Log Entries
The following is a sample of a major event log entry.
Major event log for Subsystem 001100A0B8060166 at Wed Nov 29
17:38:27 2000
Sequence Number
Time Stamp
Event Type
Event Category
Component Type
Enclosure
Slot (0-based)
Event Priority
The following is a sample of an Asynchronous Event Log entry:
Controller log sense for Subsystem 001100A0B8060166 at Mon Dec
12:51:34 2000
Controller Time Stamp = 032307 083318
FRU Code
FRU Code Qualifier
Sense Key
Additional Sense Code = 0x3F
Add Sense Code Qual
Decoded Field Replaceable Unit Information:
FRU Group
FRU ID Setting
FRU Type
Managing the Disk Array Using Array Manager 60
310
= 14
= Wed Nov 29 17:38:19 2000
= Global Hot Spare Not Large Enough (224F)
= Notification
= Disk
= 5
= 3
= Informational
= 0x08
= 0x8142
= 0x06
= 0xC7
= Sub-Enclosure Group
= 1
= Power Supply
4