Six Disk Enclosure Configurations

High Availability/High Performance
Hardware Configuration
– Two disk array controllers connected directly to host Fibre Channel adapters
– Six disk enclosures with ten 73 GByte disks each (60 disks total)
– Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
LUN Configuration
– Ten RAID 0/1 LUNs, each comprising six disks (3+3)
– Each disk in a LUN is in a separate enclosure
High Availability
– Handles a single disk failure, single BCC failure, single channel failure, or a single
controller failure
Disk Capacity
– Maximum capacity 4380 GBytes
– Usable capacity 2190 GBytes
Recommended Disk Array Configurations