HP Surestore Disk Array 12h - And FC60 Advanced User's Manual page 106

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Figure 36
Basic Topology, High Availability Version: Host with Four Fibre Channel I/O Adapters
The non-high availability version of this topology connects a host or server to one or more
single-controller module disk arrays. This version provides no hardware redundancy and
does not protect against single points of controller module, Fibre Channel cable, host Fibre
Channel I/O adapter, or internal Ultra2 SCSI bus failure. If any of these components fail, the
disk array becomes unavailable and applications cannot continue to run. The disk array
remains unavailable until the failed hardware component is replaced. Applications can
continue to run after the failure of single disk modules within logical disk units (LUNs).
Figure 37
shows the non-high availability version of the basic topology implemented on
either a
-Class or T-Class host with four Fibre Channel I/O adapters connected to single
K
Topologies for HP-UX
106

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents