Table 44
SCSI Sense Codes (cont'd)
Additional
Additional
Sense
Sense Code
Code
Qualifier
21
00
24
00
25
00
26
00
28
00
29
00
Status Conditions and Sense Code Information
330
Interpretation
Logical Block Address Out of Range
The controller received a command that requested an operation
at a logical block address beyond the capacity of the logical
unit. This error could be in response to a request with an illegal
starting address or a request that started at a valid logical block
address and the number of blocks requested extended beyond
the logical unit capacity.
Invalid Field in CDB
The controller received a command from the initiator with an
unsupported value in one of the fields in the command block.
Logical Unit Not Supported
The addressed logical unit is currently unconfigured. An Add
LUN operation in the Logical Array Mode Page must be exe-
cuted to define the logical unit before it is accessible.
Invalid Field in Parameter List
The controller received a command with a parameter list that
contained an error. Typical errors that return this code are
unsupported mode pages, attempts to change an unchange-
able mode parameter, or attempts to set a changeable mode
parameter to an unsupported value.
Not Ready to Ready Transition
The controller has completed its initialization operations on the
logical unit and it is now ready for access.
Power On, Reset, or Bus Device Reset Occurred
The controller has detected one of the above conditions.