HP Surestore Disk Array 12h - And FC60 Advanced User's Manual page 51

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

fails. RAID-0 provides enhanced performance through simultaneous I/Os to multiple disk
modules. Software mirroring the RAID-0 group provides high availability.
Figure 18
illustrates the distribution of user and parity data in a four-disk RAID 0 LUN. The
the stripe segment size is 8 blocks, and the stripe size is 32 blocks (8 blocks times 4 disks).
The disk block addresses in the stripe proceed sequentially from the first disk to the
second, third, and fourth, then back to the first, and so on.
Figure 18
LUN
RAID 0
RAID 1
RAID 1 uses mirroring to achieve data redundancy. RAID 1 provides high availability and
good performance, but at the cost of storage efficiency. Because all data is mirrored, a
RAID 1 LUN has a storage efficiency of 50%.
A RAID 1 LUN consists of exactly two disks configured as a mirrored pair. One disk is the
data disk and the other is the disk mirror. The disks in a RAID 1 LUN are mirrored by the
disk array hardware, which automatically writes data to both the data disk and the disk
mirror. Once bound into a RAID 1 mirrored pair, the two disks cannot be accessed as
Disk Array High Availability Features
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents