Table 44
SCSI Sense Codes (cont'd)
Additional
Additional
Sense
Sense Code
Code
Qualifier
40
NN
43
00
Status Conditions and Sense Code Information
336
Interpretation
Diagnostic Failure on Component NN (0x80 - 0xFF)
The controller has detected the failure of an internal controller
component. This failure may have been detected during opera-
tion as well as during an on-board diagnostic routine. The val-
ues of NN supported in this release of the software are listed
below.
80 - Processor RAM
81 - RAID Buffer
82 - NVSRAM
83 - RAID Parity Assist (RPA) chip or cache holdup battery
84 - Battery Backed NVSRAM or Clock Failure
91 - Diagnostic Self Test failed non-data transfer components
test
92 - Diagnostic SelfTest failed data transfer components test
93 - Diagnostic SelfTest failed drive Read/ Write Buffer data
turnaround test
94 - Diagnostic Self Test failed drive Inquiry access test
95 - Diagnostic Self Test failed drive Read/ Write data turn-
around test
96 - Diagnostic Self Test failed drive Self Test
Message Error
The controller attempted to send a message to the host, but the
host responded with a Reject message.