Table 44
SCSI Sense Codes (cont'd)
Additional
Additional
Sense
Sense Code
Code
Qualifier
A6
00
A7
00
C0
00
D0
06
D1
0A
E0
XX
Interpretation
Recovered processor memory failure
The controller has detected and corrected a recoverable error
in processor memory.
Recovered data buffer memory error
The controller has detected and corrected a recoverable error
in the data buffer memory.
Sense bytes 34-36 will contain the count of errors encountered
and recovered
The Inter-controller Communications Have Failed
The controller has detected the failure of the communications
link between redundant controllers.
Drive IO Time-out
The controller destination IO timer expired while waiting for a
drive command to complete.
Drive Reported Busy Status
A drive returned a busy status in response to a command.
Destination Channel Error
XX = 00 through 07 indicates the Sense Key returned by the
drive after a check condition status
XX = 10 indicates that a bus level error occurred
Status Conditions and Sense Code Information