0x00:0x00:0x00,
-,OPEN-V,10000,LBA,Disable,0x0005}],Num. of LDEVs=1
[Install]
Install function
Install CV
Install CV operation
No parameter
No parameter is selected in the above example. This operation uses the following parameters, as
shown in
Table
128.
Table 128 Parameters for Install CV Operation
Parameter
Description
No parameter
Formatted Install CV.
Non Format
Unformatted Install CV.
Progress Close
The progress window of LDEV format is closed.
Quick Format
Quick Format is selected
Quick Format Close
The progress window of preparing for Quick Format is closed.
NOTE:
No parameters are selected for any case other than those described in this table.
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
If enabled, detailed information displays for this operation, as shown in
Table 129 Install CV Operation
Item
Description
PG
The parity group number
LDKC:CU:LDEV
The LDKC, CU, and LDEV numbers
SLOT
The slot number
Emulation
The emulation type
Size
The CV capacity
Unit
The CV unit capacity
168
Install Function
Table
129.