Detailed Information
Detailed information displays for this operation, as shown in
Table 204 Replace Operation
Item
Parts name
SFP
Num.of SFPs
PCB
Failed
Num. of PCBs
Physical Device
(PDEV)
Copy
Diagnosis
Micro Program
Num. of PDEV
FSW
Num. of FSWs

Restore Operation

Example 1 (restoring a PCB)
228
Maintenance Function
Description
The name of the parts (EPOSW, PCICON, PCIADP, DKCPANEL, PSxx, PS-xx, BATTERY-xx,
ACBOX-x, FAN-xx, TH-xx, SSVP/MN, SVP, HDDFANxx-x, BATTERY-Uxxx, BATREG-x,
FUSE-xxx, ACBOX-Uxxx, DKUPS-xxx, SVRxxx-x, SVRxxx-Ex, EXTADP, BATTERY-SBx,
SBADP, or LEDPNLxx-x) specified to be replaced.
The port which Small Form-Factor Pluggables (SFPs) are inserted.
The number of inserted Small Form-Factor Pluggables (SFPs).
The mounting location of the PCB, (Channel Adapter (CHA), Disk Adapter (DKA), cache
memory, CM, SM, cache switch, MIX or BASE) to be replaced.
When replacing multiple PCBs and some of the PCBs to be replaced had failures, the
mounting locations of the failed PCBs are indicated. In such case, Warning is output as
the result of the process.
NOTE:
This information is not output when there are no failed PCBs.
The number of PCBs to be replaced.
The mounting location of the PDEVs (physical devices) to be replaced.
The status of copy process when replacing physical devices (PDEVs). This information is
output only when replacing PDEVs.
Restore Data: Data recovery from spare disk, Correction Copy: correction copy
Diagnosis is output only when INLINE skip is selected when replacing PDEVs. This
information is output only when replacing PDEVs.
Micro Program is output only when microcode update is skipped when replacing PDEVs.
This information is output only when replacing PDEVs.
The number of PDEVs to be replaced. This information is output only when easy replacing
PDEVs.
The mounting location of fibre switches to be replaced.
The number of fibre switches to be replaced.