Download Print this page

Symbols Used In Detailed Parameter Information - HP StorageWorks XP20000/XP24000 - Disk Array Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96071, december 2009)
Hide thumbs Also See for StorageWorks XP20000/XP24000 - Disk Array:

Advertisement

No.
Item
Operation result or received
9
command result
Identification information for
10
host sending the log
Identification information for
11
application
Log information sequence
12
number
1
A date and a time being set on SVP are output as log data. If a failure, such as a SVP failure and a LAN failure, occurs in
the storage system, the date and time may be output with the date and time of January 01, 1970.
2
Function names are used as section titles in
3
Operation or event names are used as subsection titles in
titles in
Chapter 44
on page 337.
Table 3
shows the symbols used in the detailed information.
Table 3 Symbols Used in Detailed Parameter Information
Symbol
Definition
+ or - appears at the beginning of a line.
+ means the beginning of the index. The number of occurrences of + represents the number of
+ and -
indents.
- means that the line continues from the previous line.
=
Connects an index and a setting value.
Explanation
The end result of your operation or the result of the received
commands.
1.
Operation result
• Normal end. The operation has ended normally.
• Error (xxxx-yyyyy). The operation has ended abnormally
and an error code appears.
• Warning (xxxx-yyyyy). The operation has partly ended
abnormally or was canceled during the operation.
Error codes are described as xxxx-yyyyy. For more informa-
tion, see HP StorageWorks XP24000/XP20000 Remote Web
Console Error Codes. SVP operations do not output error
codes.
2.
Received command result
• Normal end. The FC-SP authentication has ended nor-
mally.
• Error. The FC-SP authentication has ended abnormally.
• Accept. Received the commands from the host.
• Reject. Rejected the commands from the host.
Displays identification information (WWN, IPv4 address, IPv6
address, and serial number) of the host that sent the command.
For more information, see
This information is output when commands are received from the
host.
Displays application identification information. For more
information, see
Chapter 44
This information is output when commands are received from the
host. However, the information is not output when FC-SP are
received.
The sequence number of the saved log information (0000000000
to 4294967295). When the number reaches 4,294,967,295, it
is reset to 0000000000.
Chapter 4
on page 53.
Chapter 4
on page 53. Interface names are used as subsection
XP24000/XP20000 Audit Log User and Reference Guide
Chapter 44
on page 337.
on page 337.
35

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Storageworks xp24000Storageworks xp20000