Restore Data operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 206 Restore Data Operation
Item
PDEV
Size Change Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Size Change,,Normal end,,,Seq.=xxxxx
+PCB=[CACHE-2CB],Num. of PCBs=1
+SIZE=4096
+{Battery,Define}=[{BATTERY-12/BATTERY-22,Install}],Num. of Battery Pairs=1
[Maintenance]
Maintenance function
Size Change
Size Change operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 207 Size Change Operation
Item
PCB
Num. of PCBs
SIZE
Battery
230
Maintenance Function
Description
The mounting location of the PDEV.
Description
The mounting location of the PCB (cache memory - CM) to be replaced.
The number of PCBs to be replaced.
The capacity of cache memory.
The mounting location of the battery to be replaced. Not output when no batteries are
installed or uninstalled.
Table
206.
Table
207.