Item
Service
Num. of Types
Threshold Value Operation
Example 1
user-name,xx,YYYY/MM/DD,HH:MM:SS.xx, 00:00,[Information],Threshold Value,Alter,Normal end,,,Seq.=xxxxx
+Type=7days
+{Mechanical error(Recovered,Unrecd.),Media error(Recovered,Unrecd.),
Read/Write error(Recovered,Unrecd.),Drive I/F error(Recovered,Unrecd.),
Controller hardware error(Recovered,Unrecd.),FC I/F error Port 0(Unrecd.),
FC I/F error Port 1(Unrecd.),Port 0 error(Unrecd.),Port 1 error(Unrecd.)}
={(150,60),(0,15),(150,30),(150,6),(150,6),6,6,12,12}
++PDEV=[HDDR00-01,HDDR00-02,(snip)],Num. of PDEVs=1152
Example 2
user-name,xx,YYYY/MM/DD,HH:MM:SS.xx, 00:00,[Information],Threshold Value,Error Reset,Normal end,,,Seq.=xxxxx
+PDEV=HDDR00-01
[Information]
Information function
Threshold Value
Threshold Value operation
Alter and Error Reset
Alter is the selected parameter for example 1 and Error Reset is the selected parameter for example
2. This operation uses the parameters shown in
Table 103 Parameters for Threshold Value Operation
Parameter
Alter
Error Reset
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Description
Report service level information as SIM.
ON: Report, OFF: Do not report
The number of information levels to be reported as SIM.
Description
Change the threshold of failed PDEV (physical device).
Indicates Error Reset.
XP24000/XP20000 Audit Log User and Reference Guide
Table
103.
147