Download Print this page

Change-Cachemode Operation; Blockpaths(Fibre) Operation; Parameters For Change-Cachemode Operation - HP StorageWorks XP20000/XP24000 - Disk Array Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96071, december 2009)
Hide thumbs Also See for StorageWorks XP20000/XP24000 - Disk Array:

Advertisement

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Ext Stor],BlockPaths(FIBRE),,Normal end,,,Seq.=xxxxx
+{Port,WWN,Result}=[{1A,50560E8000C3E211,Normal end},{1A,50560E8000C3E211,Normal end},
{2A,50560E8000C3E212,Normal end}],Num. of Paths=3
[Ext Stor]
HP XP External Storage Software function
BlockPaths(FIBRE)

BlockPaths(FIBRE) operation

Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 84 BlockPaths(FIBRE) Operation
Item
Port
WWN
Result
Num. of Paths

Change-CacheMode Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Ext Stor],Change-CacheMode,Enable,Normal end,,,Seq.=xxxxx
+{Group,Result}=[{E1-1,Normal End},{E1-2,Error(605-3003)},{E1-3,Normal End},
{E1-4,Normal End}],Num. of Groups=XXX
[Ext Stor]
HP XP External Storage Software function
Change-CacheMode
Change-CacheMode operation
Enable
Enable is the selected parameter. The operation uses the parameters shown in
Table 85 Parameters for Change-CacheMode Operation
Parameter
Enable
Description
The port name of the external port of the local storage system.
The WWN of the Target port of the external storage system.
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of mapping paths that has been disconnected.
Description
The cache memory is used.
XP24000/XP20000 Audit Log User and Reference Guide
Table
84.
Table
85.
131

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Storageworks xp24000Storageworks xp20000