Download Print this page

System Option Operation; Parameters For Set Subsystem Time Operation; Set Subsystem Time Operation - HP StorageWorks XP20000/XP24000 - Disk Array Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96071, december 2009)
Hide thumbs Also See for StorageWorks XP20000/XP24000 - Disk Array:

Advertisement

Set Subsystem Time

Set Subsystem Time operation

TOD Change and Synchro. Infor
TOD Change is the selected parameter for example 1, and Synchro. Infor is the selected parameter
for example 2. This operation uses the following parameters, as shown in
Table 153 Parameters for Set Subsystem Time Operation
Parameter
TOD Change
Synchro. Infor.
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 154 Set Subsystem Time Operation
Item
Time
Use Synchro.
SNTP IP
SNTP Port
Time Zone
Check Time

System Option Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],System Option,,Normal end,,,Seq.=xxxxx
+Spare Disk Recover=Full Speed
+Disk Copy Pace=Slower
+Copy Operation(Correction Copy)=OFF
+Copy Operation(Dynamic Sparing)=OFF
+Read Configuration Data Mode=OFF
+Power Lost Mode=Destage Mode
+Cache Segment Size(SideA,SideB)=64(64,64)
+Link Failure Threshold=10
+Power Supply Type=3-phase AC Box(40A)
186
Install Function
Description
The date and the time.
The setting of time correction function.
Description
Indicates the date and the time in the format of YYYY/MM/DD HH:mm:SS .(YYYY: year,
MM: month, DD: date, HH: hour, mm: minute, SS. second).
Indicates whether the time correction function is valid or invalid.
Valid: Enable, Invalid: Disable
The IP address (IPv4 or IPv6) of SNTP server.
The port used by SNTP server.
The time zone.
The time when the time correction function is executed. Only HH (Hour: 00 to 23) is
indicated for the execution time.
Table
153.
Table
154.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Storageworks xp24000Storageworks xp20000