Detailed Information
Detailed information displays for this operation, as shown in
Table 254 Change Async Option
Item
CLPR
Rate (%)

Change Consistency Group (CTG) Option Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[TC], Change CTG Option,,Normal end,,,Seq.=xxxxx
+{LDKC,CTG, Offloading(min.),Inflow Control,Copy Pending(min.),RCU Ready(min.),
Timer Type}=
{0x00,0x00,090,Enable,05,05,System}
[TC]
TrueCopy for Mainframe function (for IBM z/OS)
Change CTG Option
Change Consistency Group Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 255 Change CTG Option Operation
Item
LDKC
CTG
Offloading (min.)
Inflow Control
Copy Pending
(min.)
RCU Ready (min.)
282
TrueCopy (TC) for Mainframe Function
Description
The CLPR number.
The specified pending update data rate.
Description
The LDKC number.
The consistency group number of the consistency group (CT group) that the option is
changed.
The value set to the offloading timer of the sidefile. The unit is minute.
Indicates whether the inflow control to the cache is enabled or disabled.
Enable: Setting is enabled, Disable: Setting is disabled
The setting value for Time Out (Copy Pending). The unit is minute. When Time Out (Copy
Pending) is set to 0 (zero), None is output.
The setting value for Time Out (RCU ready). The unit is minute. When Time Out (RCU
ready) is set to 0 (zero), None is output.
Table
254.
Table
255.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Storageworks xp24000Storageworks xp20000