Electronic Expansion Valve (Exv) Board; 2-Step Switch Controlled - Carrier 30XA080-500 Controls, Start-Up, Operation, Service And Troubleshooting Instructions

Air-cooled liquid chillers
Table of Contents

Advertisement

Actual start-up
42
Alarms and alerts
67
Alarm codes
68-72
Alarm descriptors
72-_'_2
Capacity control
16
Capacity control overrides
20
Compressor stages and circuit cycling
16
Compressor starts and run hours
16
CCN
Con{fi*rtLink
TM
CCN communication
wiring
15
Interface
15
CCN control
29
CCN global schedule
29
CCN tables
101-112
Condenser coils
Cleaning E-coated coils
64
Condenser fans
65
Configuration set point limits
30
Control methods
29
CCN control
29
CCN global schedule
29
Switch control
29
Time schedule
29
Unit run status
30
Controls
4-41
Board addresses
14
Capacity control
16
Carrier Comfort Network@ interface
15
(km{#,rtLink display menu structure
4
Configuring the master chiller
17
Configuring the slave chiller
18
Control methods
29
Control module communication
14
Demand limit
.;2
Dual chiller control
15
Electronic expansion valve (EXV) Board
9
Emergency on/off switch
13
Enable-off-remote contact switch
13
Energy management module (EMM)
13, 14
inputs and outputs
14
EXV board inputs and outputs
10
Fan board A outputs
12
Fan board C inputs and outputs
13
Fan board X outputs
12
Fan boards
11
Local equipment network
14
Low ambient temperature head pressure
control
22
Machine control
29
Main Base Bo:trd
4
Main Base Board inputs and outputs
5
Navigator
TM
module
3
Ramp loading
15
Remote alarm and alert relays
40
Temperature reset
31
Cooler heat bolts
Tightening
63
Cooler protection
66
Chilled water flow switch
64
Freeze protection
62
Loss of fluid flow protection
62
Low fluid temperature
62
Plug components
63
Tightening cooler heat bolts
63
Tube plugging
62
INDEX
Cooling
set point selection
SO
4 to 20mA
input
30
Configuration
set point limits
30
Control
methods and cooling set points
table,
30
Dual switch
30
Ice mode
30
Set point 1
30
Set point 2
30
Set point occupancy
30
Denmnd limit
$2
2-step switch controlled
32
2-step switch controlled
configuration
table
39
CCN loadshed controlled
40
Demand limit signal
41
Externally
powered
40
Externally
powered
den]and
limit
configuration
table
40
Electronic
expansion
valve
56
Cutaway
view of
57
Filter drier
59
Inspecting/opening
.58
Installing
motor
.5;_
Liquid line service valve
59
Moisture
liquid indicator
.5_'_
Troubleshooting
procedure
57
Freeze protection
62
Head pressure
control. See low ambient
temperature
head pressure control
Loss of fluid flow protection
62
Low ambient
head pressure
control
22
Fan Staging
23, 24
Operating
instructions
22
Low fluid temperature
62
Machine
control
29
Maintenance
66
Minimum
and nmximum
cooler flow rotes
43
Minimum
fluid loop volume
42
Navigator
display
Con_fl,rtLink
alarms mode
4, 100
O*mfl*rtLink configuration
mode
4, 9.5,96
Comfl*rtLink
inputs mode
4, 93
()m_fl*rtLink
operating
mode
4, 100
Comfl*rtLink
outputs
mode
4, 94
C>n_ibrtLink
pressure mode
4, 91
Cbn_fl*rtLink rnn status mode
4, 8Z &_¢
O,mfl,rtLink
service test mode
4, 82, 89
()m_fl*rtLink
set points mode
4, 92
O*mfl*rtLink temperature
mode
4, 90
Om_tortLink
time clock mode
4, 97-99
Navigator
module
3
Adjusting
the backlight
brightness
3
Adjusting
the contrast
3
Co11_fi,rtLink display menu structure
4
Operating
linfitations
42
Flow rote requirements
42
Minimum
and nmximum
cooler
flow rates
43
Minimum
fluid loop volume
42
Voltage
42
Plug components
63
Recommended
maintenance
schedule
66
Every 12 months
(.¢_
Every 3 months
(.¢_
Monthly
66
Routine
66
Refrigerant
circuit
65
Refrigerant
feed components
Electronic
expansion
valve
56
Relief devices
66
Safety considerations
2
Safety devices
66
Compressor
protection
66
Service
56-r'.¢_
Coil maintenance
and cleaning
64
Compressors
59
Condenser
fans
65
Cooler protection
61
Electronic
expansion
valve (EXV)
56
Refrigerant
circuit
65
Relief devices
66
Safety devices
66
Start-up
42-48
Actual start-up
42
Operating
limitations
42
Pre-start-up
41
System check
41
Start-up and operation.
See Start-up
Checklist
Start-up checklist
CL- I m C1-8
Switch control
29
System check
41
Temperature
linfits
Low ambient
operation
22
Temperature
reset
31
4to 20mA temperature
reset
36
4 to 20mA temperature
reset configuration
table
38
Chilled
water tempemturecontrol
34
Outdoor
air temperature
reset
34
Outdoor
air temperature
reset configuration
table
35
Return water reset configuration
33
Space ten]perature
reset
36
Space ten]perature
reset configuration
$7
Thermistors
.52
Compressor
return gas temperature
52
Cooler entering fluid sensor
.52
Cooler leaving fluid sensor
.52
Dual chiller LWT
53
Outdoor
air temperature
52
Remote space temperature
.52
Typical space temperature
sensor
wiring
53
Time schedule
29
Transducers
53, .5.5
Troubleshooting
66-86
Service test
82
Tube plugging
62
Copyright 2005 Carrier Corporation
Manufacturer reserves the right to discontinue,
or change at any time, specifications
or designs without notice and without incurring obligations.
Catalog No. 533-00069
Printed in U.S.A.
Form 30XA-1T
Pg 118
12-05
Replaces:
New

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents