Carrier 30XA080-500 Controls, Start-Up, Operation, Service And Troubleshooting Instructions page 112

Air-cooled liquid chillers
Table of Contents

Advertisement

APPENDIX
B -- CON TABLES
(cont)
SERVICE CONFIGURATION
TABLES
TABLE
DEFAULT
WRITE STATUS
SERVICE
DISPLAY NAME
Cooler Fluid Type
Brine Flow Switch SP
Brine Freeze Setpoint
Condenser
Fluid Type
Entering
Fluid Control
Prop PID Gain Varifan
Int PID Gain Varifan
Deri PID Gain Varifan
EXV A Superheat
Setpoint
EXV B Superheat
Setpoint
EXV C Superheat
Setpoint
Pinch offset circuit A
Pinch offset circuit B
Pinch offset circuit C
EXV MOP Setpoint
High Pressure Threshold
Cooler Heater Delta Spt
Auto Start When SM Lost
Recl Valve Min Position*
Recl Valve Max Position*
Economizer
SH Setpoint A
Economizer
SH Setpoint B
Economizer
SH Setpoint C
User Password
RANGE
1-3
1
10
14
1/2
1
Yes/No
No
-20.0-20,0
2.0
-5.0-5,0
0,2
20.0-20,0
0.4
5-15
7,2
5-15
7,2
5-15
7.2
-3.0-3.0
0
-3.0-3,0
0
-3.0-3,0
0
40-55
55
500-640
609
1-6
2
Enable/Disable
Disable
0-50
20
20-100
100
5-15
7,2
5-15
7,2
5-15
7,2
0-150
11
UNITS
°F
AF
^F
^F
^F
^F
^F
^F
°F
psi
^F
%
%
^F
^F
^F
POINT NAME
flui typ
flowsp
Iowestsp
cond typ
ewt opt
hd pg
hd ig
hd dg
sh spa
sh sp b
sh sp c
)inoff a
)inoff b
)inoff c
mop sp
hpth
heatersp
auto
sm
rain 3w
max 3w
esh_p
a
esh sp b
esh sp c
use pass
*Not supported.
NOTE: This table shall be downloadable
at any time. However, modified value shall not be used by tasks until the unit is in OFF state. This shall not apply to the Varifan
gains that shall be modified at any time and used immediately
by the head pressure control tasks even if the unit is in operation.
TABLE
I
DISPLAY NAME
I
RANGE
I
UNITS
I
POINT NAME
I
WRITE STATUS
TABLE TO BE USED FOR RUN TIMES UPDATE IN CASE OF CONTROL
RETROFIT
UPDHRFAN
FAN Operating
Hours
Circuit A Fan #1 Hours
Circuit A Fan #2 Hours
Circuit A Fan #3 Hours
Circuit A Fan #4 Hours
Circuit A Fan #5 Hours
Circuit A Fan #6 Hours
Circuit A Fan #7 Hours
Circuit A Fan #8 Hours
Circuit A Fan #9 Hours
Circuit A Fan #10 Hours
Circuit B Fan #1 Hours
Circuit B Fan #2 Hours
Circuit B Fan #3 Hours
Circuit B Fan #4 Hours
Circuit B Fan #5 Hours
Circuit B Fan #6 Hours
Circuit B Fan #7 Hours
Circuit B Fan #8 Hours
Circuit B Fan #9 Hours
Circuit B Fan #10 Hours
Circuit C Fan #1 Hours
Circuit C Fan #2 Hours
Circuit C Fan #3 Hours
Circuit C Fan #4 Hours
Circuit C Fan #5 Hours
Circuit C Fan #6 Hours
Circuit C Fan #7 Hours
Circuit C Fan #8 Hours
Circuit C Fan #9 Hours
Circuit C Fan #10 Hours
WATER PUMP #1 Hours*
WATER PUMP #2 Hours*
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
hours
hr fanal
hours
hr fana2
hours
hr fana3
hours
hr fana4
hours
hr fana5
hours
hr fana6
hours
hr fana7
hours
hr fana8
hours
hr fana9
hours
hrfanal 0
hours
hr fanbl
hours
hr fanb2
hours
hr fanb3
hours
hr fanb4
hours
hr fanb5
hours
hr fanb6
hours
hr fanb7
hours
hr fanb8
hours
hr fanb9
hours
hrfanbl 0
hours
hr fancl
hours
hr fanc2
hours
hr fanc3
hours
hr fanc4
hours
hr fanc5
hours
hr fanc6
hours
hr fanc7
hours
hr fanc8
hours
hr fanc9
hours
hrfancl0
hours
hr cpurnl
hours
hr cpurn2
*Not supported.
NOTE: This table shall be used for purposes
of transplanting
the devices on time in the event of a module hardware failure or software upgrade via downloading.
It shall
be usable only if all items are still null. Afterwards,
its access shall be denied.
TABLE
I
DISPLAY NAME
I
RANGE
I
UNITS
I
POINT NAME
I
WRITE STATUS
TABLE TO BE USED FOR RUN TIMES UPDATE IN CASE OF CONTROL
RETROFIT
UPDTHOUR
Machine
Operating
Hours
nnnnn
Machine
Starts
Compressor
A Hours
Compressor
A Starts
Compressor
B Hours
Compressor
B Starts
Compressor
C Hours
Compressor
C Starts
Circuit A Defrost Number*
Circuit B Defrost Number*
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
nnnnn
hours
hours
hours
hours
hr mach
st roach
hr cp a
st cp a
hr cp b
st cp b
hr cp c
st cp c
nb defa
nb defb
*Not supported.
NOTE: This table shall be used for purposes
of transplanting
the devices on time in the event of a module hardware failure or software upgrade via downloading.
It shall
be usable only if all items are still null. Afterwards,
its access shall be denied.