Sign In
Upload
Manuals
Brands
Carrier Manuals
Chiller
AQUASNAP 30RBP Series
Carrier AQUASNAP 30RBP Series Chiller Manuals
Manuals and User Guides for Carrier AQUASNAP 30RBP Series Chiller. We have
2
Carrier AQUASNAP 30RBP Series Chiller manuals available for free PDF download: Installation, Operation And Maintenance Instructions
Carrier AQUASNAP 30RBP Series Installation, Operation And Maintenance Instructions (104 pages)
Air-Cooled Liquid Chillers, Reversible heat pumps
Brand:
Carrier
| Category:
Chiller
| Size: 9 MB
Table of Contents
Table of Contents
3
Introduction and Safety Instructions
5
Receipt of Goods
5
Checking the Equipment Received
5
Handling and Positioning
6
Handling
6
Positioning
6
Dimensions, Clearances, Minimum Installation Distances
8
30RB/30RBP and 30RQ/30RQP Dimensions Without Buffer Tank Module (Option 307)
8
30RB/30RBP and 30RQ/30RQP Dimensions with Buffer Tank Module (Option 307)
10
Free Spaces
11
Positioning of Potentially Flammable Zones Around the Unit
11
Installing Several Units
11
Distance to the Wall
11
Physical and Electrical Data for the Units
12
Physical Data 30RB 170R-380R
12
Physical Data 30RB 410R-950R
13
Physical Data 30RBP 170R to 950R
14
Physical Data 30RQ 165R-520R
16
Physical Data 30RQP 165R-520R
17
Physical Data 30RQP 620R-1040R
18
Electrical Data 30RB 170R-950R
19
Electrical Data 30RBP 170R-950R
20
Electrical Data 30RQ 165R-520R
21
Electrical Data 30RQP 165R-1040R
21
Short Circuit Withstand Current
22
Electrical Data for the Hydraulic Module
24
Electrical Data Notes for the Compressors
30
Distribution of Compressors Per Circuit
30
Comments on Electrical Data Notes
31
Electrical Connection
32
Power Supply
32
Voltage Phase Imbalance (%)
32
Power Connection/Disconnect Switch
32
Recommended Cable Sections
32
Power Cable Access Routing
34
Field-Installed Control Wiring
34
Electric Power Reserve for the User
34
Application Data
35
Operating Range
35
Minimum Energy Transfer Fluid Flow Rate (Units Without Factory-Fitted Hydraulic Module)
37
Maximum Energy Transfer Fluid Flow Rate (Units Without Factory-Fitted Hydraulic Module)
37
Variable Flow Water Type Heat Exchanger (Units Without Factory-Fitted Hydraulic Module)
37
Minimum System Water Volume
37
Maximum System Water Volume
37
Water Type Heat Exchanger Water Flow Rate
38
Pressure Drop Curves for the Water Type Heat Exchanger and Standard Water Inlet/Outlet Piping
39
Water Connections
41
Operating Precautions and Recommendations
41
Hydraulic Connections
42
Hydraulic Connections for 30RQP 620R-1040R Units
44
Flow Rate Detection
46
Cavitation Protection (with Hydraulic Module Option)
46
Additional Electrical Heaters
46
Frost Protection
47
Nominal System Water Flow Rate Control
48
Units Without Hydraulic Module
48
Units with Hydraulic Module and Fixed-Speed Pump
48
Units with Hydraulic Module and Variable-Speed Pump - Pressure Differential Control
49
Units with Hydraulic Module and Variable-Speed Pump - Temperature Differential Control
50
Units with Hydraulic Module and Variable-Speed Pump - Setting a Fixed Flow Rate for the System
50
Available Static System Pressure
51
System Start-Up
56
Checks before System Start-Up
56
Commissioning
56
Essential Points to Check
57
Main Components of the Unit and Operating Characteristics
58
Compressors
58
Lubricant
58
Air-Cooled Exchanger
58
Fans
59
Electronic Expansion Valve (EXV)
60
Moisture Indicator
60
Dehumidifier Filter
60
Refrigerant Accumulator with Built-In Filter Drier
60
Water Type Heat Exchanger
60
Refrigerant
60
High-Pressure Safety Pressostat
60
Variable Frequency Drive
60
Fan Arrangement
61
Fan Stages
63
Variable Speed Ventilation (30RBP/30RQP Units)
64
Smartvu TM Control
64
Options
65
Tables of Options
65
Description
68
Standard Maintenance
95
Level 1 Maintenance
95
Level 2 Maintenance
95
Level 3 Maintenance
96
Tightening the Electrical Connections
96
Tightening Torques for the Main Fastenings
97
Air-Cooled Exchanger
97
Water Type Heat Exchanger
97
Variable Frequency Drive
97
Refrigerant Volume
98
Refrigerant Properties
98
Final Shut-Down
99
Shutting down
99
Recommendations for Disassembly
99
Fluids to be Recovered for Treatment
99
Materials to be Recovered for Recycling
99
Waste Electrical and Electronic Equipment (WEEE)
99
Unit Start-Up Checklist for Installers Prior to Contacting the Manufacturer
100
Advertisement
Carrier AQUASNAP 30RBP Series Installation, Operation And Maintenance Instructions (76 pages)
Air-Cooled Liquid Chillers
Brand:
Carrier
| Category:
Chiller
| Size: 11 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Safety Considerations Related to Protection Devices
4
Refrigerant Safety Considerations
5
Installation Safety Considerations
7
Maintenance Safety Considerations
7
Repair Safety Considerations
8
2 Receipt of Goods
9
Check Equipment Received
9
3 Handling and Positioning
9
Handling
9
Positioning
10
4 Dimensions, Clearances
11
30Rbm/Rbp 160-260
11
30Rbm/Rbp 300-400
11
30Rbm/Rbp 430-520
13
Installing Several Units
17
Distance to the Wall
17
5 Physical and Electrical Data for the Units
18
Physical Data 30RBM 160-520
18
Physical Data 30RBP 160-520
19
Electrical Data 30RBM 160-520
20
Electrical Data 30RBP 160-520
20
Short Circuit Stability Current
20
Electrical Data Notes for the Hydraulic Module
21
Electrical Data Notes for the Compressors
22
Distribution of Compressors Per Circuit
22
Electrical Data Notes
23
6 Electrical Connection
24
Power Supply
24
Voltage Phase Imbalance (%)
24
Recommended Wire Sections
24
Power Cable Entry
25
Field Control Wiring
25
Electric Power Reserve for the User
25
Power Connection/Disconnect Switch
25
7 Application Data
26
Operating Range
26
Minimum Heat Transfer Fluid Flow Rate (Units Without Factory-Fitted Hydraulic Module)
27
Maximum Heat Transfer Fluid Flow Rate (Units Without Factory-Fitted Hydraulic Module)
27
Variable Flow Evaporator (Units Without Factory-Fitted Hydraulic Module)
27
System Minimum Water Volume
27
System Maximum Water Volume
27
Water Type Heat Exchanger Water Flow Rate
28
Pressure Drop Curves for the Water Type Heat Exchanger and Standard Water Inlet/Outlet Piping
29
8 Water Connections
30
Operating Precautions and Recommendations
30
Water Connections
31
Cavitation Protection (with Hydraulic Option)
33
Water Flow Rate Detection
33
Frost Protection
33
9 Nominal System Water Flow Rate Control
35
Units Without Hydraulic Module
35
Units with Hydraulic Module and Fixed Speed Pump
36
Units with Hydraulic Module and Variable Speed Pump - Pressure Differential Control
37
Units with Hydraulic Module and Variable Speed Pump - Temperature Differential Control
38
Units with Hydraulic Module and Variable Speed Pump - Setting a Fixed Flow Rate for the System
38
Available Static Pressure for the System
39
10 System Start-Up
43
Checks before System Start-Up
43
Commissioning
43
Essential Points to Check
44
11 Main Components of the Unit and Operating Characteristics
44
Compressors
44
Lubricant
44
Air-Cooled Exchanger
44
Fans
45
Electronic Expansion Valve (EXV)
46
Moisture Indicator
46
Filter Drier
46
Water Type Heat Exchanger
46
Refrigerant
46
High-Pressure Safety Pressostat
46
Variable Frequency Drive
46
Fan Arrangement
47
Fan Stages
47
Variable Speed Ventilation
47
Fan Motor Electrical Protection
47
12 Options
48
Tables of Options
48
Description
50
13 Standard Maintenance
67
Level 1 Maintenance
67
Level 2 Maintenance
67
Level 3 Maintenance
68
Tightening of the Electrical Connections
68
Tightening Torques for the Main Fastenings
68
Air-Cooled Exchanger
69
Water Type Heat Exchanger
69
Variable Frequency Drive
69
Refrigerant Volume
69
Refrigerant Properties
70
Power Factor Correction
70
14 Final Shutdown
71
Shutting down
71
Recommendations for Disassembly
71
Fluids to be Recovered for Treatment
71
Materials to be Recovered for Recycling
71
Waste Electrical and Electronic Equipment (WEEE)
71
15 Unit Start-Up Checklist for Installers Prior to Contacting the Manufacturer
72
Advertisement
Related Products
Carrier 30RBP 160
Carrier 30RBP 180
Carrier 30RBP 200
Carrier 30RBP 220
Carrier 30RBP 260
Carrier 30RBP 300
Carrier 30RBP 330
Carrier 30RBP 360
Carrier 30RBP 400
Carrier 30RBP 470
Carrier Categories
Air Conditioner
Heat Pump
Furnace
Chiller
Thermostat
More Carrier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL