Table 3. DSA diagnostic messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 "Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798" on page 205 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
Message
number
Component
201-807-xxx
Memory
201-808-xxx
Memory
201-809-xxx
Memory
92
ThinkServer RD220 Hardware Maintenance Manual
Test
State
Description
Memory
Aborted
Test canceled:
Test
the memory
controller
buffer free
request failed.
Memory
Aborted
Test canceled:
Test
memory
controller
display/alter
buffer execute
error.
Memory
Aborted
Test canceled
Test
program error:
operation
running fast
scrub.
Action
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the system UEFI code
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For
the latest level of firmware, go to
http://www.ibm.com/support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system to
display a matrix of available firmware.
4. Run the test again.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the system UEFI code
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For
the latest level of firmware, go to
http://www.ibm.com/support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system to
display a matrix of available firmware.
4. Run the test again.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the DSA code
is at the latest level. For the
latest level of DSA code, go to
http://www.ibm.com/support/docview.wss?uid=psg1SERV-D
4. Make sure that the system UEFI code
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For
the latest level of firmware, go to
http://www.ibm.com/support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system to
display a matrix of available firmware.
5. Run the test again.