Attention: For proper cooling and airflow, replace the cover before you turn on the server. Operating
the server for extended periods of time (over 30 minutes) with the cover removed might damage server
components.

Installing the server cover

Attention: For proper cooling and airflow, install the server cover before you turn on the server.
To install the server cover, complete the following steps:
1. Align the cover over the server until the cover edges slip in position over the chassis.
2. Press down the cover-release latch
front of the server until the cover is completely closed.

Removing the operator information panel assembly

To remove the operator information panel
Step 1.
Remove the cover.
Step 2.
Disconnect the cable from the back of the operator-information panel
Step 3.
Reach inside the server and press the release tab; then, while holding the release tab down, push
the assembly toward the front of the server.
Step 4.
From the front of the server, carefully pull the operator information panel assembly out of the server.
1
on the front of the cover, while sliding the cover forward toward the
2
assembly, complete the following steps.
2
assembly.
.