Lenovo ThinkServer RD220 Hardware Maintenance Manual page 36

Hardware maintenance manual for rd220
Hide thumbs Also See for ThinkServer RD220:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 "Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798" on page 205 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
Error code
Description
162
Device configuration error.
163
Real-time clock error. (time of day not set)
184
Power-on password damaged.
30
ThinkServer RD220 Hardware Maintenance Manual
Action
1. Run the Server Configuration and Boot
Management program, select Load Default
Settings, and save the settings.
2. Reseat the following components, one at a time, in
the order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then
it must be reseated by a trained service
technician only)
3. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then
it must be replaced by a trained service
technician only)
c. (Trained service technician only) System board
1. Run the Server Configuration and Boot
Management program, select Load Default
Settings, make sure that the date and time are
correct, and save the settings.
2. Reseat the battery.
3. Clear CMOS memory. See "System-board
switches and jumpers" on page 132 for information
about how to clear CMOS memory.
4. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. Battery
b. (Trained service technician only) System board
1. Restart the server and enter the administrator
password; then, run the Server Configuration and
Boot Management program, select Load Default
Settings, and save the settings.
2. Reseat the battery.
3. Clear CMOS memory. See "System-board
switches and jumpers" on page 132 for information
about how to clear CMOS memory.
4. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. Battery
b. (Trained service technician only) System board