1
Adapter connector
2
Signal cable
16. Reinstall the front fan cage assembly. Align the front fan cage assembly over the fan cage assembly slot
and with the connector on the system board. Lower the fan cage assembly into the chassis and press
down firmly until the fan cage assembly is seated firmly in place. Make sure that no cables will be pinched.
17. Reinstall the air baffle (see "Installing the air baffle" on page 251).
18. Rotate the power-supply cage assembly back into the server. Press the power-supply cage release tab
and rotate the power-supply cage assembly into the chassis.
1
Power supply support bracket
2
Power supply release tab
19. If you have other options to install or remove, do so now.
20. Replace the side cover (see "Installing the side cover" on page 252). Go to "Completing the installation"
on page 249.
If you have other options to install or remove, do so now. Otherwise, go to "Completing the installation" on
page 249.

Installing the optional ServeRAID-MR10is VAULT SAS/SATA controller

The optional ServeRAID-MR10is VAULT SAS/SATA controller can be installed only in its dedicated connector,
PCI slot 1, on the system board. The ServeRAID-MR10is adapter is supported on hot-swap server models
only. The ServeRAID-MR10is SAS/SATA adapter with an encryption 1078 DE chip set enables integrated
RAID levels 0, 1, 5, 6, 10, 50, and 60 support capability on hot-swap hard disk drives. For configuration
information, see the documentation on the ServeRAID CD that comes with the adapter.
.