Lenovo TD200 - ThinkServer - 3809 Hardware Maintenance Manual page 223

Hardware maintenance manual
Hide thumbs Also See for TD200 - ThinkServer - 3809:
Table of Contents

Advertisement

Note: DIMM connectors 1, 4, 9, and 12 are not functional in this server. Do not install DIMMs
in these connectors.
1
DIMM 1 (reserved)
2
DIMM 2
3
DIMM 3
4
DIMM 4 (reserved)
5
DIMM 5
6
DIMM 6
7
DIMM 7
8
DIMM 8
Step 6.
Open the retaining clips on DIMM connector.
Attention: To avoid breaking the retaining clips or damaging the DIMM connectors, open and
close the clips gently.
Step 7.
Touch the static-protective package that contains the DIMM to any unpainted metal surface on the
server; then, remove the new DIMM from the package.
Step 8.
Turn the DIMM so that the DIMM keys align correctly with the connector.
9
DIMM 9 (reserved)
10
DIMM 10
11
DIMM 11
12
DIMM 12 (reserved)
13
DIMM 13
14
DIMM 14
15
DIMM 15
16
DIMM 16
Chapter 7
.
Installing and replacing FRUs
215