• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836" on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
3xx0007 (xx
Firmware fault detected, system halted
can be 00 -
19)
3038003
Firmware corrupted
3048005
Booted secondary (backup) UEFI Image
3048006
Booted secondary (backup) UEFI image
because of ABR
3058000A
RTC date/time is incorrect
Action
1. Recover the server firmware to the latest level (see
"Updating the firmware" on page 306).
2. Undo any recent configuration changes, or clear
CMOS memory to restore the settings to the default
values.
3. Remove any recently installed hardware.
1. Run the Setup utility, select Load Default Settings,
and save the settings to recover the server
firmware.
2. (Trained service technician only) Replace the
system board.
Information only. The backup switch was used to boot
the secondary bank.
1. Run the Setup utility, select Load Default Settings,
and save the settings to recover the primary UEFI
settings.
2. Turn off the server and remove it from the power
source.
3. Reconnect the server to the power source, then
turn on the server.
1. Adjust the date and time settings in the Setup
utility, and then restart the server.
2. Reseat the battery.
3. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. Battery
b. (Trained service technician only) System board
29
.