12. Connect the configuration signal cable. See "Power and signal cables for internal drives" on page 182 for
information about cabling the power and signal cables.
13. Complete the cabling of the ServeRAID-BR10i SAS/SATA adapter.
• For the eight drive-bay, 2.5 inch server model, connect one end of the signal cable to the drive
backplane for drive bays 0 through 3 and route the other end through the plastic slot on the bottom
of the chassis underneath the front fan cage; then, connect it to the ServeRAID-BR10i SAS/SATA
controller as shown in the following illustrations:
1
Signal cable for drives 0-3 (backplane labeled A0)
2
Adapter connector for drives 0-3 signal cable
The following illustration shows the connectors on the controller to which you connect the signal
cables from the drive backplanes.
1
ServeRAID-BR10i controller
2
Adapter connector for drives 0-3 signal cable
3
Adapter connector for drives 4-7 signal cable
Connect one end of the other signal cable to the drive backplane for drive bays 4 through 7 and
route the other end of the cable through the plastic slots on the bottom of the chassis underneath
.
Chapter 7
Installing and replacing FRUs
229