• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836" on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
The Drive n Status has been
removed from unit Drive 0 Status.(n
= hard disk drive number)
The Drive n Status has been disabled
due to a detected fault.(n = hard disk
drive number)
Array %1 is in critical
condition.(%1 =
CIM_ComputerSystem.ElementName)
Array %1 has failed.(%1 =
CIM_ComputerSystem.ElementName)
Memory uncorrectable error
detected for DIMM All DIMMs on
Memory Subsystem All DIMMs.
Error
A drive has been removed.
Error
A drive has been disabled
because of a fault.
Error
An array is in Critical
state.(Sensor = Drive n
Status)(n = hard disk drive
number)
Error
An array is in Failed
state.(Sensor = Drive n
Status)(n = hard disk drive
number)
Error
A memory uncorrectable
error has occurred.
Reseat hard disk drive n.(n = hard
disk drive number)
1. Run the hard disk drive
diagnostic test on drive n.
2. Reseat the following
components:
a. Hard disk drive
b. Cable from the system
board to the backplane
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Hard disk drive
b. Cable from the system
board to the backplane
c. Hard disk drive backplane
(n = hard disk drive number)
Replace the hard disk drive that is
indicated by a lit status LED.
Replace the hard disk drive that is
indicated by a lit status LED.
1. If the server failed the POST
memory test, reseat the
DIMMs.
2. Replace any DIMM that is
indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.
3. Run the Setup utility to enable
all the DIMMs.
4. Run the DSA memory test.
.
Chapter 5
Diagnostics
41