• For the four drive-bay, 3.5 inch server model, connect the signal cable as shown in the following
illustration:
1
Adapter connector
2
Signal cable
14. Reinstall the front fan cage assembly. Align the front fan cage assembly over the fan cage assembly slot
and with the connector on the system board. Lower the fan cage assembly into the chassis and press
down firmly until the fan cage assembly is seated firmly in place. Make sure that no cables will be pinched.
15. Reinstall the air baffle (see "Installing the air baffle" on page 251).
16. Rotate the rear adapter-retention bracket to the closed (locked) position.
17. Rotate the power-supply cage assembly back into the server. Press the power-supply cage release tab
and rotate the power-supply cage assembly into the chassis.
1
Power supply support bracket
2
Power supply release tab
If you have other options to install or remove, do so now. Otherwise, Go to "Completing the installation" on
page 249.

Installing the optional ServeRAID-MR10i SAS/SATA controller

The optional ServeRAID-MR10i SAS/SATA controller can be installed only in its dedicated connector, PCI
slot 1, on the system board. The ServeRAID-MR10i adapter is supported on hot-swap server models
only. The ServeRAID-MR10i SAS/SATA adapter enables integrated RAID levels 0, 1, 5, 6, 10, 50, and 60
support capability on hot-swap hard disk drives. For configuration information, see the documentation on
the ServeRAID CD that comes with the adapter.
.