6.4
Quick way to clean X-cutter
Here's procedure for quick way to clean X-cutter.
Note that this indicates only the way of cleaning, and If mal-cutting still persists after
cleaning according the way below, then replacement of X-cutter unit according
disassembly procedure of Chapter 3 is necessary.
1. Disassemble machine to the extent of Fig.3.3-11 ( Like Fig. 6.4-1 below )
Fig. 6.4-1 Disassemble machine
2. Remove Y-CA chassis screws and Y-extension spring L to remove Y-CA chassis Assy,
with chassis still assembled with bottom cover.
Fig. 6.4-2
Removing Y-CA chassis Assy
6-20