Installation and MERLIN LEGEND System Programming
Table 1-6
Switch
1
2
3
4
NOTE:
During a power outage there is no need to use battery backup to answer calls
if the MERLIN Attendant shares an Uninterruptible Power Supply (UPS) with
the MERLIN LEGEND system control unit. If a UPS is not being used with the
control unit, during a power failure incoming calls cannot be answered by the
system and therefore cannot be directed to the MERLIN Attendant.
1-20
Connecting the MERLIN Attendant
Switch Settings When Operating Unit
Setting
Saves recorded announcements
O n
during power outage
Saves routes and programmable
O n
features during power outage
Does not use battery backup to
Off
answer calls during power outage
(See NOTE)
Not Used
OFF
Result