Agilent Technologies 3458A User Manual page 91

Hide thumbs Also See for 3458A:
Table of Contents

Advertisement

Trigger Arm
Trigger
Event
Event
SGL
SYN
SYN
SGL
SYN
AUTO, EXT, TIMER,
LINE, LEVEL
SYN
AUTO
SYN
SYN
AUTO
AUTO, EXT, TIMER,
LINE, LEVEL
SYN
EXT
AUTO, EXT, TIMER,
LINE, LEVEL
SYN
EXT
SYN
SYN
LEVEL AUTO, EXT, TIMER,
LEVEL
SYN
LEVEL SYN, LINE
SYN
LINE
AUTO, EXT, TIMER,
LINE
SYN
LINE
SYN, LEVEL
SYN
SGL
Any
SYN
SYN
SYN
SYN
SYN
AUTO, EXT, TIMER,
LINE, LEVEL
1
The LEVEL event occures when the specified voltage is reached on the specified slope of the input
signal. The LEVEL trigger event or sample event can only be used for DC voltage or direct-sampled
measurements.
2
The output buffer must be empty and reading memory must be OFF or empty for the SYN event to occur.
3
The input buffer must be enabled or you must suppress cr lf when sending the TARM SGL command.
Table 21. Event Combinations
Sample
Event
After executing the TARM SGL command, followed by the
controller requesting data
the first reading is taken. One reading is then taken per SYN
event until the specified number of readings are completed.
The trigger arm event then becomes HOLD.
After executing the TARM SGL command, followed by the
controller requesting data,
event until the specified number of readings are completed.
The trigger arm event then becomes HOLD.
After the controller requests data,
events) the first reading is taken. One reading is then taken
per SYN event until the specified number of readings are
completed.
After the controller requests data,
sample event until the specified number of readings are
completed.
After the controller requests data,
edge transition on the Ext Trig input, one reading is taken per
sample event until the specified number of readings are
completed.
Illegal
After the controller requests data,
occurrence of the LEVEL event,
sample event until the specified number of readings are
completed
Illegal
After the controller requests data,
voltage crossing zero volts, one reading is taken per sample
event until the specified number of readings are completed.
Illegal
Illegal
After the controller requests data,
satisfied and the first reading is taken. One reading is then
taken per SYN event until the specified number of readings
are completed.
After the controller requests data,
satisfied. One reading is then taken per sample event until the
specified number of readings are completed.
Description
2
, which satisfies both SYN events,
2
one reading is taken per sample
2
(which satisfies both SYN
2
one reading is taken per
2
followed by a negative
2
followed by the
1
one reading is taken per
2
followed by the power line
2
all three events are
2
both SYN events are
Chapter 4 Making Measurements
3
3
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents